The product is represented by a lateral flow device able to measure the presence of 2 soluble factors in a urine sample. The combination of these molecules will allow to have an indication on carrying out the biopsy examination to the patient for the diagnosis of prostatic carcinoma.
Lateral flow devices are immunochromatographic analytical methods, less precise than other screening methods based on immunological assays such as ELISA, but sufficiently sensitive, quantitative and accurate. A lateral flow device consists of a sample pad where the sample is deposited, a conjugate pad in which a tracer is adsorbed, a membrane where the binding reaction takes place on which there are two active sites, one for testing and one of control, and finally an absorbent pad responsible for directing the flow through the membrane. When the sample is loaded onto the sample pad, it moves to the conjugate pad where it solubilizes the tracer (generally an anti-analyte antibody adsorbed to colloidal go...
The product is represented by a lateral flow device able to measure the presence of 2 soluble factors in a urine sample. The combination of these molecules will allow to have an indication on carrying out the biopsy examination to the patient for the diagnosis of prostatic carcinoma.
Lateral flow devices are immunochromatographic analytical methods, less precise than other screening methods based on immunological assays such as ELISA, but sufficiently sensitive, quantitative and accurate. A lateral flow device consists of a sample pad where the sample is deposited, a conjugate pad in which a tracer is adsorbed, a membrane where the binding reaction takes place on which there are two active sites, one for testing and one of control, and finally an absorbent pad responsible for directing the flow through the membrane. When the sample is loaded onto the sample pad, it moves to the conjugate pad where it solubilizes the tracer (generally an anti-analyte antibody adsorbed to colloidal gold particles). The flow of liquid moves by capillarity through the membrane towards the areas where the reagents of the two test lines are stored (Test and Control Line).
When the sample contains quantities of an analyte above a certain threshold, an analyte-antibody-tracer complex is formed which is recognized by the antibody of the test line and precipitates, forming a colored band of intensity proportional to the concentration of analyte in the sample. Thanks to the absorbent pad, the flow of liquid continues even when the membrane is completely moist towards the control line, consisting of capture antibodies that bind the tracer independently of the concentration of the analyte in the sample. In the event that the control line has not been colored at the end of the test, the test is considered invalid.
The product proposed by us is a multi-analyte lateral flow device, that is, it has 3 different test lines, one for each analyte of interest.

Based on how many test lines are visible, the exam will immediately return one of the 3 possible results:
• 0-1 lines: Do not perform biopsy
• 2 line: Perform the biopsy, in conjunction with other suspicious factors
• 3 line: Perform the biopsy
More information